"Requested_prod_id","Requested_GTIN(EAN/UPC)","Requested_Icecat_id","ErrorMessage","Supplier","Prod_id","Icecat_id","GTIN(EAN/UPC)","Category","CatId","ProductFamily","ProductSeries","Model","Updated","Quality","On_Market","Product_Views","HighPic","HighPic Resolution","LowPic","Pic500x500","ThumbPic","Folder_PDF","Folder_Manual_PDF","ProductTitle","ShortDesc","ShortSummaryDescription","LongSummaryDescription","LongDesc","ProductGallery","ProductGallery Resolution","ProductGallery ExpirationDate","360","EU Energy Label","EU Product Fiche","PDF","Video/mp4","Other Multimedia","ProductMultimediaObject ExpirationDate","ReasonsToBuy","Spec 1","Spec 2","Spec 3","Spec 4","Spec 5","Spec 6","Spec 7","Spec 8","Spec 9","Spec 10","Spec 11","Spec 12","Spec 13","Spec 14","Spec 15","Spec 16","Spec 17","Spec 18","Spec 19","Spec 20","Spec 21","Spec 22","Spec 23","Spec 24","Spec 25","Spec 26","Spec 27","Spec 28","Spec 29","Spec 30","Spec 31","Spec 32","Spec 33","Spec 34","Spec 35","Spec 36","Spec 37","Spec 38","Spec 39","Spec 40" "","","34387549","","APC","AP7920B","34387549","0731304331612|731304331612","Power Distribution Units (PDUs)","984","","","AP7920B","20240314191821","ICECAT","1","200153","https://images.icecat.biz/img/gallery/34387549_4086578077.jpg","2187x769","https://images.icecat.biz/img/gallery_lows/34387549_4086578077.jpg","https://images.icecat.biz/img/gallery_mediums/34387549_4086578077.jpg","https://images.icecat.biz/img/gallery_thumbs/34387549_4086578077.jpg","","","APC AP7920B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black","1U, 12A/208V, 10A/230V, 50/60 Hz, 8x IEC 320 C13, IEC-320 C14, 445 x 108 x 44 mm, 2270 g","APC AP7920B, Metered, Switched, 0U/1U, Horizontal/Vertical, Black, 8 AC outlet(s), C13 coupler","APC AP7920B. PDU types: Metered, Switched, Rack capacity: 0U/1U, Mounting: Horizontal/Vertical. AC outlets quantity: 8 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler. Cable length: 1,98 m, Certification: cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL.... Monitoring: Current, Power, Voltage, Outlet control: Lock-out, Recycle, Turn off, Turn on. Nominal input voltage: 200-230 V, Maximum current: 10 A, AC input frequency: 50 - 60 Hz","Availability\n\nIntegrates with StruxureWare Data Center Expert\nAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.\n\nFlash Upgradeable\nQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.\n\nLocal Current Monitoring Display\nThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.\n\nAlarm Thresholds\nDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.\n\nLoad indicator LED\nIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.\n\nPower Delays\nAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.\n\nRemote Individual Outlet Control\nRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).\n\nNetwork Management Capabilities\nFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.\n\nMarketing Features\n\nPower Delays\nAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.\n\nRemote Individual Outlet Control\nRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).\n\nLocal Current Monitoring Display\nThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.\n\nRemote Management Capabilities\nFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.\n\nAlarm Thresholds\nDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.\n\nAgility\n\nWide range of input and output connections\nProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.\n\nSingle input power source\nSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.\n\nRack-Mountable\nIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.","https://images.icecat.biz/img/gallery/34387549_4086578077.jpg|https://images.icecat.biz/img/gallery/34387549_1971615528.jpg","2187x769|2273x752","|","","","","","","","","","Design","PDU types: Metered, Switched","Rack capacity: 0U/1U","Mounting: Horizontal/Vertical","Product colour: Black","Ports & interfaces","AC outlets quantity: 8 AC outlet(s)","AC outlet types: C13 coupler","Power plug: C14 coupler","Input connection type: IEC-320 C14","Features","Cable length: 1,98 m","Certification: cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH","Management features","Monitoring: Current, Power, Voltage","Outlet control: Lock-out, Recycle, Turn off, Turn on","Power","Nominal input voltage: 200-230 V","Maximum current: 10 A","AC input frequency: 50 - 60 Hz","Nominal output voltage: 208-230 V","Load capacity: 2300 VA","Maximum input current per phase: 10 A","Maximum total current draw per phase: 10 A","Maximum power: 2300 W","Weight & dimensions","Dimensions (WxDxH): 445 x 108 x 44 mm","Weight: 2,27 kg","Packaging data","Package dimensions (WxDxH): 470 x 343 x 70 mm","Package weight: 3,45 kg","Operational conditions","Operating temperature (T-T): 0 - 45 °C","Storage temperature (T-T): -25 - 65 °C","Operating relative humidity (H-H): 0 - 95%","Storage relative humidity (H-H): 0 - 95%","Operating altitude: 0 - 3000 m","Non-operating altitude: 1 - 15000 m","Technical details","Sustainability certificates: RoHS"